Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
R Soc Open Sci ; 10(6): 221067, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37388315

RESUMO

To evaluate the synchronization of bivariate time series has been a hot topic, and a number of measures have been proposed. In this work, by introducing the ordinal pattern transition network into the crossplot, a new method for measuring the synchronization of bivariate time series is proposed. After the crossplot been partitioned and coded, the coded partitions are defined as network nodes and a directed weighted network is constructed based on the temporal adjacency of the nodes. The crossplot transition entropy of the network is proposed as an indicator of the synchronization between two time series. To test the characteristics and performance of the method, it is used to analyse the unidirectional coupled Lorentz model and compared it with existing methods. The results showed the new method had the advantages of easy parameter setting, efficiency, robustness, good consistency and suitability for short time series. Finally, electroencephalogram (EEG) data from auditory-evoked potential EEG-biometric dataset are investigated, and some useful and interesting results are obtained.

2.
Sensors (Basel) ; 23(5)2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-36905065

RESUMO

An error-related potential (ErrP) occurs when people's expectations are not consistent with the actual outcome. Accurately detecting ErrP when a human interacts with a BCI is the key to improving these BCI systems. In this paper, we propose a multi-channel method for error-related potential detection using a 2D convolutional neural network. Multiple channel classifiers are integrated to make final decisions. Specifically, every 1D EEG signal from the anterior cingulate cortex (ACC) is transformed into a 2D waveform image; then, a model named attention-based convolutional neural network (AT-CNN) is proposed to classify it. In addition, we propose a multi-channel ensemble approach to effectively integrate the decisions of each channel classifier. Our proposed ensemble approach can learn the nonlinear relationship between each channel and the label, which obtains 5.27% higher accuracy than the majority voting ensemble approach. We conduct a new experiment and validate our proposed method on a Monitoring Error-Related Potential dataset and our dataset. With the method proposed in this paper, the accuracy, sensitivity and specificity were 86.46%, 72.46% and 90.17%, respectively. The result shows that the AT-CNNs-2D proposed in this paper can effectively improve the accuracy of ErrP classification, and provides new ideas for the study of classification of ErrP brain-computer interfaces.


Assuntos
Algoritmos , Interfaces Cérebro-Computador , Humanos , Eletroencefalografia/métodos , Redes Neurais de Computação , Sensibilidade e Especificidade
3.
Artigo em Inglês | MEDLINE | ID: mdl-36355738

RESUMO

Brain-computer interface (BCI) based on motor imagery (MI) electroencephalogram (EEG) has become an essential way for rehabilitation, because of the activation and interaction of motor neurons between the brain and rehabilitation devices in recent years. However, due to the discrepancies between individuals, the frequency ranges can be different even for the same rhythm component of EEG recordings, which brings difficulties to the extraction of features for MI classification. Typical algorithms for MI classification such as common spatial patterns (CSP) require multi-channel analysis and lack frequency information. With the development of BCI, the single-channel BCI system has become indispensable for simplicity of use. However, the currently available single-channel detection methods have low classification accuracy. To address this issue, two novel frameworks based on an improved two-dimensional nonlinear FitzHugh-Nagumo (FHN) neuron system are proposed to extract features of the single-channel MI. To evaluate the effectiveness of the proposed methods, this research utilized an open-access database (BCI competition IV dataset 2a), an offline database, and a 10-fold cross-validation procedure. Experimental results showed that the improved nonlinear FHN system can transfer the energy of noise into MI, thereby effectively enhancing the time-frequency energy. Compared with the traditional methods, the proposed methods can achieve higher classification accuracy and robustness.


Assuntos
Interfaces Cérebro-Computador , Imaginação , Humanos , Imaginação/fisiologia , Processamento de Sinais Assistido por Computador , Eletroencefalografia/métodos , Algoritmos , Neurônios Motores
4.
J Neural Eng ; 18(5)2021 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-34571497

RESUMO

Objective.Motor imagery (MI), based on the theory of mirror neurons and neuroplasticity, can promote motor cortical activation in neurorehabilitation. The strategy of MI based on brain-computer interface (BCI) has been used in rehabilitation training and daily assistance for patients with hemiplegia in recent years. However, it is difficult to maintain the consistency and timeliness of receiving external stimulation to neural activation in most subjects owing to the high variability of electroencephalogram (EEG) representation across trials/subjects. Moreover, in practical application, MI-BCI cannot highly activate the motor cortex and provide stable interaction owing to the weakness of the EEG feature and lack of an effective mode of activation.Approach.In this study, a novel hybrid BCI paradigm based on MI and vestibular stimulation motor imagery (VSMI) was proposed to enhance the capability of feature response for MI. Twelve subjects participated in a group of controlled experiments containing VSMI and MI. Three indicators, namely, activation degree, timeliness, and classification accuracy, were adopted to evaluate the performance of the task.Main results.Vestibular stimulation could significantly strengthen the suppression ofαandßbands of contralateral brain regions during MI, that is, enhance the activation degree of the motor cortex (p< 0.01). Compared with MI, the timeliness of EEG feature-response achieved obvious improvements in VSMI experiments. Moreover, the averaged classification accuracy of VSMI and MI was 80.56% and 69.38%, respectively.Significance.The experimental results indicate that specific vestibular activity contributes to the oscillations of the motor cortex and has a positive effect on spontaneous imagery, which provides a novel MI paradigm and enables the preliminary exploration of sensorimotor integration of MI.


Assuntos
Interfaces Cérebro-Computador , Neurônios-Espelho , Eletroencefalografia , Humanos , Imagens, Psicoterapia , Imaginação
5.
Front Neurosci ; 15: 716051, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34489633

RESUMO

The purpose of this study was to enhance the performance of steady-state visual evoked potential (SSVEP)-based visual acuity assessment with spatial filtering methods. Using the vertical sinusoidal gratings at six spatial frequency steps as the visual stimuli for 11 subjects, SSVEPs were recorded from six occipital electrodes (O1, Oz, O2, PO3, POz, and PO4). Ten commonly used training-free spatial filtering methods, i.e., native combination (single-electrode), bipolar combination, Laplacian combination, average combination, common average reference (CAR), minimum energy combination (MEC), maximum contrast combination (MCC), canonical correlation analysis (CCA), multivariate synchronization index (MSI), and partial least squares (PLS), were compared for multielectrode signals combination in SSVEP visual acuity assessment by statistical analyses, e.g., Bland-Altman analysis and repeated-measures ANOVA. The SSVEP signal characteristics corresponding to each spatial filtering method were compared, determining the chosen spatial filtering methods of CCA and MSI with a higher performance than the native combination for further signal processing. After the visual acuity threshold estimation criterion, the agreement between the subjective Freiburg Visual Acuity and Contrast Test (FrACT) and SSVEP visual acuity for the native combination (0.253 logMAR), CCA (0.202 logMAR), and MSI (0.208 logMAR) was all good, and the difference between FrACT and SSVEP visual acuity was also all acceptable for the native combination (-0.095 logMAR), CCA (0.039 logMAR), and MSI (-0.080 logMAR), where CCA-based SSVEP visual acuity had the best performance and the native combination had the worst. The study proved that the performance of SSVEP-based visual acuity can be enhanced by spatial filtering methods of CCA and MSI and also recommended CCA as the spatial filtering method for multielectrode signals combination in SSVEP visual acuity assessment.

6.
Front Neurosci ; 15: 757679, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35069096

RESUMO

The refresh rate is one of the important parameters of visual presentation devices, and assessing the effect of the refresh rate of a device on motion perception has always been an important direction in the field of visual research. This study examined the effect of the refresh rate of a device on the motion perception response at different stimulation frequencies and provided an objective visual electrophysiological assessment method for the correct selection of display parameters in a visual perception experiment. In this study, a flicker-free steady-state motion visual stimulation with continuous scanning frequency and different forms (sinusoidal or triangular) was presented on a low-latency LCD monitor at different refresh rates. Seventeen participants were asked to observe the visual stimulation without head movement or eye movement, and the effect of the refresh rate was assessed by analyzing the changes in the intensity of their visual evoked potentials. The results demonstrated that an increased refresh rate significantly improved the intensity of motion visual evoked potentials at stimulation frequency ranges of 7-28 Hz, and there was a significant interaction between the refresh rate and motion frequency. Furthermore, the increased refresh rate also had the potential to enhance the ability to perceive similar motion. Therefore, we recommended using a refresh rate of at least 120 Hz in motion visual perception experiments to ensure a better stimulation effect. If the motion frequency or velocity is high, a refresh rate of≥240 Hz is also recommended.

7.
Int Ophthalmol ; 41(2): 587-598, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33044670

RESUMO

PURPOSE: Traditional color vision tests depend on subjective judgments and are not suitable for infant children and subjects with cognitive dysfunction. We aimed to explore an objective and quantitative color vision testing method based on sweep steady-state visual evoked potentials (sweep SSVEPs) and compare the results with subjective Farnsworth-Munsell (FM) 100-hue test results. METHODS: A red-green SSVEP pattern reversal checkboard paradigm at different luminance ratios was used to induce visual evoked potentials (VEPs) from 15 color vision deficiencies (CVDs) and 11 normal color vision subjects. After electroencephalography signals were processed by canonical correlation analysis, an equiluminance turning curve corresponding to the activation of the L-cones and M-cones at different levels of color vision was established. Then, we obtained different equiluminance T and proposed the SSVEP color vision severity index (ICVD) to quantify color vision function and the severity of CVDs. In addition, the FM 100-hue test was used to obtain subjective data for the diagnosis of color vision. RESULTS: The value of ICVD can be an indicator of the level of color vision. Both the total error scores (TES) and confusion index (C-index) of the FM 100-hue test were significantly correlated with ICVD values (P < 0.001, respectively). ICVD also had a good classification effect in detecting normals, anomalous trichromats and dichromats. Moreover, equiluminance T had a good effect on classifying protans and deutans in subjects with CVDs. CONCLUSION: Color vision evaluation with sweep SSVEPs showed a good correlation with subjective psychophysical methods. SSVEPs can be an objective and quantitative method to test color vision and diagnose CVDs.


Assuntos
Defeitos da Visão Cromática , Visão de Cores , Criança , Percepção de Cores , Testes de Percepção de Cores , Defeitos da Visão Cromática/diagnóstico , Potenciais Evocados Visuais , Humanos , Testes Visuais
8.
Sensors (Basel) ; 20(19)2020 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-32998208

RESUMO

Visual evoked potential (VEP) has been used as an alternative method to assess visual acuity objectively, especially in non-verbal infants and adults with low intellectual abilities or malingering. By sweeping the spatial frequency of visual stimuli and recording the corresponding VEP, VEP acuity can be defined by analyzing electroencephalography (EEG) signals. This paper presents a review on the VEP-based visual acuity assessment technique, including a brief overview of the technique, the effects of the parameters of visual stimuli, and signal acquisition and analysis of the VEP acuity test, and a summary of the current clinical applications of the technique. Finally, we discuss the current problems in this research domain and potential future work, which may enable this technique to be used more widely and quickly, deepening the VEP and even electrophysiology research on the detection and diagnosis of visual function.


Assuntos
Potenciais Evocados Visuais , Visão Ocular , Acuidade Visual , Adulto , Eletroencefalografia , Humanos , Lactente
9.
PLoS One ; 11(9): e0163426, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27658216

RESUMO

Steady-state visual evoked potentials (SSVEP) based paradigm is a conventional BCI method with the advantages of high information transfer rate, high tolerance to artifacts and the robust performance across users. But the occurrence of mental load and fatigue when users stare at flickering stimuli is a critical problem in implementation of SSVEP-based BCIs. Based on electroencephalography (EEG) power indices α, θ, θ + α, ratio index θ/α and response properties of amplitude and SNR, this study quantitatively evaluated the mental load and fatigue in both of conventional flickering and the novel motion-reversal visual attention tasks. Results over nine subjects revealed significant mental load alleviation in motion-reversal task rather than flickering task. The interaction between factors of "stimulation type" and "fatigue level" also illustrated the motion-reversal stimulation as a superior anti-fatigue solution for long-term BCI operation. Taken together, our work provided an objective method favorable for the design of more practically applicable steady-state evoked potential based BCIs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...